UV- systems: electronic ballasts, sensors, monitor
ZED GmbH was founded in 2001 using experience gathered since 1996.
We focus on development, production and sales of reliable and efficient electronic driver systems designed to meet the special requirements within the purification and disinfection industry.
Standard accessories, classical and highly innovative solutions complement each other.
Next generation accessories for UV systems: digital UV sensors, digital controlled electronic ballasts, control units for lamp operation and monitoring.
We focus on development, production and sales of reliable and efficient electronic driver systems designed to meet the special requirements within the purification and disinfection industry.
Standard accessories, classical and highly innovative solutions complement each other.
Next generation accessories for UV systems: digital UV sensors, digital controlled electronic ballasts, control units for lamp operation and monitoring.
Innovations & solutions
Products
show more >>
ZED SmartMeter
universal handheld unit for UV/C measurement
universal handheld unit for UV/C measurement
- UV-C intensity reference measurement with ÖNORM/DVGW compliant sensors
- VUV intensity measurement with 185nm sensors
- readjustment of digital ZED UV-C sensors
- data logging
- ModBus address setting
- VUV intensity measurement with 185nm sensors
- readjustment of digital ZED UV-C sensors
- data logging
- ModBus address setting
ZED PPT – Perfect Performance Tool
UV-C lamp optimization
UV-C lamp optimization
- lamp add-on for optimizing the UV-C output of amalgam lamps in combination with ZED ballasts
- UV-C lamp efficiency increase
- stable and predictable UV-C output in the entire temperature and dimming range
- no change in lamp/reactor geometry
- no additional wiring necessary
- UV-C lamp efficiency increase
- stable and predictable UV-C output in the entire temperature and dimming range
- no change in lamp/reactor geometry
- no additional wiring necessary
ZED Modula
compact electronic unit for UV-C systems
compact electronic unit for UV-C systems
- modular electronic unit for operating 1…3 UV-C lamps, total power 600W for easy integration into customized cabinets
- autonomous working base unit combines ballast, control- and monitoring features with a range of interfaces for integration in UV-C systems
- different front-ends for remote control
- autonomous working base unit combines ballast, control- and monitoring features with a range of interfaces for integration in UV-C systems
- different front-ends for remote control
New Line of Ballasts for Medium Pressure Lamps
The new line of ballasts for medium pressure lamps
The new line of ballasts for medium pressure lamps
Electronic ballasts for medium pressure lamps,
power ranges:
- 200...500W,
- 500...1500W
- 1500...2500W
> ignitor: internal for short cable lengths /
external for long cable lengths
> adjustable operation parameters
> lamp operation control via RS485
using ModBus or ZCON protocol
- power range control
- undervoltage protection
- overtemperature protection
- ground fault protection
optional:
dimming using analog 4...20mA/0...10V interface
power ranges:
- 200...500W,
- 500...1500W
- 1500...2500W
> ignitor: internal for short cable lengths /
external for long cable lengths
> adjustable operation parameters
> lamp operation control via RS485
using ModBus or ZCON protocol
- power range control
- undervoltage protection
- overtemperature protection
- ground fault protection
optional:
dimming using analog 4...20mA/0...10V interface
ZED Digital UVC Reference sensor
ÖNORM/DVGW compliant Digital UVC Reference sensor
ÖNORM/DVGW compliant Digital UVC Reference sensor
UVC Reference Sensor D-SiCONORM-LP-REF to be used - for calibration checks of DVGW/ÖNORM conform facility sensors - as measurement device - as reference for in-field recalibration of digital ZED sensors > digital signal processing, signal conversion to absolute UVC intensity values in W/m² > measurement ranges: 0.01..250W/m²/0.1..500W/m² > internal operation hour counter The digital ZED reference sensor itself is the complete reference device -it is not bound to a certain radiometer device
PHplus ballasts
controllable and adjustable electronic ballasts
controllable and adjustable electronic ballasts
- preheat start ballasts for optimal lamp operation
- long lamp-ballast distances - up to 30 m
- single, dual, triple and quad lamp types
- housing types and rack mountable types
- adjustable operation parameters
- dimmable
- providing local operation and digital remote control
- lamp operation control via RS485 using ModBus or ZCON
- status indication with LED, relay or via RS485
- enhanced protection: power range control, undervoltage protection, overtemperature protection
-
- long lamp-ballast distances - up to 30 m
- single, dual, triple and quad lamp types
- housing types and rack mountable types
- adjustable operation parameters
- dimmable
- providing local operation and digital remote control
- lamp operation control via RS485 using ModBus or ZCON
- status indication with LED, relay or via RS485
- enhanced protection: power range control, undervoltage protection, overtemperature protection
-
PH-S ballasts
electronic ballasts with enhanced operation
electronic ballasts with enhanced operation
- preheat start ballasts for optimal lamp operation
- long lamp-ballast distances up to 30 m
- optimized to the specified lamp
- status indication with LED and relay
- overtemperature protection
- long lamp-ballast distances up to 30 m
- optimized to the specified lamp
- status indication with LED and relay
- overtemperature protection
ZCONmini
master control unit for PHplus ballasts
master control unit for PHplus ballasts
- lamp operation control and monitoring
- operation hour counter
- UV monitoring with up to 4 digital UV sensors
- status indication by LCD, LED and relays
- remote switching
- ready to use and customized solutions
- operation hour counter
- UV monitoring with up to 4 digital UV sensors
- status indication by LCD, LED and relays
- remote switching
- ready to use and customized solutions
ZCONnano
dimming interface for PHplus ballasts
dimming interface for PHplus ballasts
- dimming interface for PLC with 4-20mA/0-10V and switching I/O
- control of up to 12 PHplus ballasts
- lamp operation control and monitoring
- status indication by LCD and relay
- ready to use, selectable operation modes
- control of up to 12 PHplus ballasts
- lamp operation control and monitoring
- status indication by LCD and relay
- ready to use, selectable operation modes
D-SiC, D-SiC-I, D-SiC-U
digital UV-C sensors with digital or analog signal
digital UV-C sensors with digital or analog signal
Sensors for use in UV-C monitoring systems.
The digital signal processing allows the automatic selection of the optimum internal measurement range.
Low pressure types are adjusted for the complete range of 2...500W/m², medium pressure types: range 20...3000W/m².
Digital UV sensors with RS485 interface enable fail safe signal transmission using ModBus or ZCON protocol.
Digital Sensors with analog output incorporate signal converter to classical analog interfaces (4-20mA, 0-2V, 0-10V).
The digital signal processing allows the automatic selection of the optimum internal measurement range.
Low pressure types are adjusted for the complete range of 2...500W/m², medium pressure types: range 20...3000W/m².
Digital UV sensors with RS485 interface enable fail safe signal transmission using ModBus or ZCON protocol.
Digital Sensors with analog output incorporate signal converter to classical analog interfaces (4-20mA, 0-2V, 0-10V).
D-ST
digital temperature sensor for UV-C systems
digital temperature sensor for UV-C systems
Temperaturesensors for use in UV-C monitoring systems. Digital signal processing and RS485 interface enable fail safe signal transmission using ModBus or ZCON protocol, max. cable length: 30m. Multi sensor operation is possible by connecting sensors in parallal to the RS485 bus.
These temperature sensors can be used with digital ZED UV-C sensors on the same RS485 bus.
These temperature sensors can be used with digital ZED UV-C sensors on the same RS485 bus.
PHplus-R ballasts
for 4x 320W / 2x 260W / 1200W UV-C lamps
for 4x 320W / 2x 260W / 1200W UV-C lamps
- optimized lamp operation - long lamp-ballast distances up to 30 m - single, dual, triple and quad lamp types - housing types and rack mountable types - adjustable operation parameters - dimmable (optional via 4-20mA, 0-10V, Ethernet) - providing local operation and digital remote control - lamp operation control via RS485 using ModBus or ZCON - status indication with LED, relay or via RS485 - enhanced protection: power range control, undervoltage/overtemperature protection